TCVN 7830: 2015, Energy efficiency of non-ducted air conditioners

Source: International Energy Agency
Last updated: 23 October 2019

TCVN 7830: 2015 replaces TCVN 7830: 2012

 

This standard applies to air conditioners without air ducts using compressor-type motors n and condenser cooled non-empty , a cluster or two clusters, with or without inverters (hereafter referred to as equipment) having an rated cooling capacity of up to 12 000 W (41 000 BTU / h). This standard also applies to air conditioners with air ducts of a nominal refrigeration capacity of less than 8 000 W and is designed to work at small external static pressures n 25 Pa. This standard does not apply to water-cooled, air-cooled, portable, floor, ceiling, air-conditioned more than two clusters or if the air conditioners use three-phase electricity.

 

SINGLE SPLIT

1-star: = 2.80

2-star: = 3.00

3-star: = 3.20

4-star: = 3.40

5-star: = 3.60

 

DOUBLE SPLIT

 

CC <4 500 W or 15 000 BTU/hr

1-star: = 3.10

2-star: = 3.40

3-star: = 3.60

4-star: = 3.80

5-star: = 4.20

 

4 500 W or 15 000 BTU/hr = CC <7 000 W or 24 000 BTU/hr

 

1-star: = 3.00

2-star: > 3.20

3-star: = 3.40

4-star: = 3.60

5-star: = 4.00

 

7 000 W or 24 000 BTU/hr = CC <12 000 W or 41 000 BTU/hr

 

1-star: = 2.80

2-star: = 3.00

3-star: = 3.20

4-star: = 3.40

5-star: = 3.80

 

Want to know more about this policy ? Learn more (Vietnamese)