NTG COGUANOR 11007 Energy Efficiency Classification for Window, Split and Package Type Air Conditioners
This regulation sets the standards for the voluntary Energy Efficiency Classification for Window, Split and Package Type Air Conditioners as follow:
Air conditioners with capacity =7038 W ( = 24000 Btu/h):
- Class A:
- window type: EER 2,69 (9,2)
- with ducts: EER 3,67 (12,5)
- ductless: EER 3,67 (12,5)
- Class B:
- window type: EER 2,57 (8,77)
- with ducts: EER 3,22 (10,98)
- ductless: EER 2,75 (9,39)
- Class C:
- window type: EER 2,34 (7,98)
- with ducts: EER 2,34 (7,98)
- ductless: EER 2,34 (7,98)
Air conditioners with capacity > 7 038 W a = 10 553 W (> 24 000 Btu/h a = 36 000 Btu/h)
- Class A:
- packaged: EER 3,67 (12,5)
- with ducts: EER 3,67 (12.5)
- ductless: EER 3,67 (12.5)
- Class B:
- window type: EER 2,26 (7,71)
- packaged: EER 3,22 (11,00)
- with ducts: EER 3,22 (11.00)
- ductless: EER 3,22 (11.00)
- Class C:
- window type: EER 2,05 (7,00)
- packaged: EER 2,60 (8,87)
- with ducts: EER 2,46 (8.39)
- ductless: EER 2,46 (8.39)
Air conditioners with capacity >10 553 W a 17 589 W (>36 000 Btu/h a 60 000 Btu/h)
- Class A:
- packaged: EER 3.67 (12.5)
- with ducts: EER 3.67 (12.5)
- ductless: EER 3.67 (12.5)
- Class B:
- packaged: EER 3.22 (11.00)
- with ducts: EER 3.22 (11.00)
- ductless: EER 3.22 (11.00)
- Class C:
- packaged: EER 2.60 (8.87)
- with ducts: EER 2.60 (8.87)
- ductless: EER 2.60 (8.87)
Want to know more about this policy ? Learn more (Spanish)