Commercial Building Energy Standards (CBES) - Vermont

Source: International Energy Agency
Last updated: 21 February 2019
Vermont Commercial Building Energy Standards (CBES) are based on 2015 IECC.
Application to replacement fenestration products
Where some or all of an existing fenestration unit is replaced with a new fenestration product, including slash and glazing, the replacement fenestration unit shall meet the applicable requirements for U-factor and SHGC.
Building Envelop Requirements
Building thermal envelop assemblies for building that are intended to comply with the code on a perspective basis, in accordance with the compliance path described in Item 2 of Section C401.2, shall comply with the following:
The opaque portion of the building thermal envelop shall comply with the specific insulation requirements of Section C402.2 and the thermal requirements of either the R-value –based method of section C 402.1.3; the U-, C-, F-Factor-based method of Section C402.1.4; or the component performance alternative of Section C402.1.5
Roof solar reflectance and thermal emittance shall comply with Section C402.3
Fenestration in building envelop assemblies shall comply with Section C402.4
Air leakage of building envelop assemblies shall comply with Section C402.5
Perspective Compliance
Vertical Fenestration: New vertical fenestration area that results in a total building fenestration area less than or equal to that specified in Section C402.4.1 shall comply with Section C402.4. Additions with vertical fenestration that result in a total building fenestration area greater than Section C402.4.1 or additions that exceed the fenestration area greater than Section C402.4.1 shall comply with Section C402.4.1.1 for the addition only. Additions that result in a total building vertical glass area exceeding that specified in Section C402.4.1.1 shall comply with Section C407.

Skylight area
New skylight area that results in a total building fenestration area less than or equal to that specified in Section C402.4.1 shall comply with Section C402.4. Additions with skylight area that result in a total building skylight area greater than Section C402.4.1 or additions that exceed the skylight area greater than Section C402.4.1 shall comply with Section C402.4.1.2 for the addition only. Additions that result in a total building skylight area exceeding that specified in Section C402.4.1.2 shall comply with Section C407.

Water heating System
New service water heating equipment, controls and service water heating piping shall comply with Section C404
Heating and Cooling System
New heating, cooling and duct systems shall comply with Sections C403
Lighting
New lighting systems shall comply with Sections C405