NOM-023-ENER-2018: Energy efficiency in split air conditioners, free discharge and without air ducts. Limits, testing and labelling methods

Last updated: 18 July 2019

This standard establishes the minimum level of seasonal energy efficiency ratio that must be met by divided air conditioners (minisplit and multisplit), of simple cycle (only cold) or reversible cycle (heat pump) in nominal capacities of cooling of 1 Wt until 19 050 Wt.

 

The MEPS established by this standard are the following:

  • Cooling capacity (CC) = 4 101 Watts (13 993 Btu/h) - Seasonal energy efficiency ratio (SEER) 3.37 Wt/We (11.5 Btu/hW)
  • 4 101 Watts (13 993 Btu/h) < CC = 5 859 Watts  (19 991.493 Btu/h) - SEER 3.37 Wt/We (11.5 Btu/hW)
  • 5 859 Watts  (19 991,493 Btu/h) < CC = 10 600 Watts  (36 168.26 Btu/h) - SEER 3.31 Wt/We (11.3 Btu/hW)
  • 10 600 Watts  (36 168.26 Btu/h) < CC = 19 050 Watts  (65 000.505 Btu/h) - SEER 3.28 Wt/We (11.2 Btu/hW)

 

Want to know more about this policy ? Learn more (Spanish)